Ventilation Tools

Tools for evaluating industrial ventilation and estimating the airflow needed to control workplace exposures.

Basics

Volumetric Flow Rate

Calculate airflow from velocity and cross-sectional area.

Open the tool →

Velocity and Velocity Pressure

Convert between duct velocity and velocity pressure.

Open the tool →

Total Pressure

Calculate total pressure from static and velocity pressure.

Open the tool →

Continuity

Solve Q = VA for airflow, velocity, or duct area.

Open the tool →

Energy Balance

Track static, velocity, and total pressure between two points in a duct system.

Open the tool →

Hood Types

Booth

Calculate the airflow a booth needs from its open face area and target face velocity.

Open the tool →

Canopy Hood

Calculate the airflow a canopy hood needs from its perimeter, height above the source, and capture velocity.

Open the tool →

USEPA Method 204

Calculate the airflow an enclosure needs from its openings and target face velocity.

Open the tool →

Plain Opening Hood

Calculate the airflow a plain opening hood needs to reach the target capture velocity.

Open the tool →

Flanged Opening Hood

Calculate the airflow a flanged opening hood needs to reach the target capture velocity.

Open the tool →

Plain Slot Hood

Calculate the airflow a slot hood needs to reach the target capture velocity.

Open the tool →

Flanged Slot Hood

Calculate the airflow a flanged slot hood needs to reach the target capture velocity.

Open the tool →

Plain Multiple Slot Hood

Calculate the airflow a plain multiple slot hood needs to reach the target capture velocity.

Open the tool →

Flanged Multiple Slot Hood

Calculate the airflow a flanged multiple slot hood needs to reach the target capture velocity.

Open the tool →

Hood Performance

Coefficient of Entry

Calculate a hood's coefficient of entry from its actual and ideal airflow.

Open the tool →

Hood Entry Loss

Calculate the pressure lost as air enters a hood.

Open the tool →

Hood Flow from SPh

Estimate hood airflow from measured hood static pressure.

Open the tool →

Hood Static Pressure

Calculate hood static pressure from velocity pressure and hood entry loss.

Open the tool →

Ducts

Junction Balancing

Balance airflow where two duct branches meet.

Open the tool →

Junction Resultant VP

Calculate the resultant velocity pressure where two duct branches combine.

Open the tool →

Fans

Fan Law 1: Flow

Predict how fan airflow changes with fan speed.

Open the tool →

Fan Law 2: Pressure

Predict how fan pressure changes with fan speed.

Open the tool →

Fan Law 3: Power

Predict how fan power changes with fan speed.

Open the tool →

Fan Static Pressure

Calculate fan static pressure from inlet and outlet conditions.

Open the tool →

Fan Total Pressure

Calculate fan total pressure from inlet and outlet total pressures.

Open the tool →

Dilution Ventilation

Air Changes per Hour

Calculate how many times per hour the air in a room is replaced, from airflow and room volume.

Open the tool →

Effective Ventilation Rate

Adjust actual airflow for incomplete mixing using a mixing factor.

Open the tool →

Dilution Air

Calculate the dilution airflow needed to keep a contaminant below a target concentration.

Open the tool →

Purge

Estimate how long it takes to purge a room down to a target concentration.

Open the tool →

Concentrations

Concentration Buildup from Zero

Estimate how room concentration builds over time when starting from zero.

Open the tool →

Concentration Buildup or Decay with Generation

Estimate how room concentration rises or falls over time while a contaminant is being generated.

Open the tool →

Steady-State Concentration

Calculate the equilibrium room concentration from generation rate and airflow.

Open the tool →

Hummel Generation Rate

Estimate a contaminant generation rate using the Hummel method.

Open the tool →

More tools will be added as they become available. Use results alongside professional judgment and your workplace requirements.

Built by OEMS to support practical, science-based workplace health decisions.